HP3000-L Archives

March 2008, Week 3

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Denys Beauchemin <[log in to unmask]>
Reply To:
Denys Beauchemin <[log in to unmask]>
Date:
Fri, 21 Mar 2008 05:48:15 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (44 lines)
Did you copy the target file to the 927 or did you just create an empty file
there?

Is the 927 also running 6.5 PP3?

Denys

-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On Behalf
Of Brian Donaldson
Sent: Friday, March 21, 2008 5:07 AM
To: [log in to unmask]
Subject: [HP3000-L] FWRITEDIR Problem

I have a COBOL program that writes 7 records to a priv mode file.

This part works ok...

I do an FWRITE to logical record #7 (physically the 8th record) and
this works just fine, a-ok.

This program is compiled and run on a 917LX under 6.5 PP3 using COB85XL


I move this source code onto our 927 box, recompile and re-run and kaboom(!)

Program aborts when the FWRITEDIR to logical record #7 fails with
an FSERR code of 40 

What I do not understand is why it works perfectly on the 917 but fails
when it is run on the 927.

Any insight as to what the problem may be would be appreciated as this is a 
major showstopper.....

TIA,
Brian Donaldson.

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2