Jeff asks:
> Is anyone using a Power Truss with the connection back from the
> Power Truss to the CPU?

The small Power Trust units were standard with 9x8 boxes (unless you deleted
it from the order), so this is a common configuration.

> I note from investigation that this will cause a smooth
> shutdown if power is lost.

For small values of "smooth".  When the batteries get low the UPS signals
the system which immediately generates a System Abort.  I believe the sole
goal is for there to be no I/O in flight at the instant the power actually
drops, which the System Abort guarantees quite well, if rather abruptly.

> Are there other features?

Not that I'm aware of.  Most of the small Power Truss (well, it's what I've
always called them too) units don't have too much exposed intelligence, or
if there's a way to get at it I don't know what it is.

G.