Check your LED's on each side of the IO bays.. Maybe start by pulling all your IO Cards.
I have seen this twice, each time being a PCI slot bad, once I changed the IO backplane on left side, second time was on HPUX, I just moved the LAN card.
Hope this helps!
Ryan C. Melander, V.P.
Ideal Computer Services, Inc.
88 Wright Brothers Ave.
Livermore, CA 94551
Ph. 800-862-8787
Ph. 925-447-4747 x213
Fx. 925-447-4780
mailto:[log in to unmask]
-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On Behalf Of Craig Lalley
Sent: Thursday, September 10, 2015 9:18 AM
To: [log in to unmask]
Subject: Re: [HP3000-L] System Bus Adapter Fail
Can you send a PIM dump?
-Craig
From: "Johnson, Tracy" <[log in to unmask]>
To: [log in to unmask]
Sent: Thursday, September 10, 2015 9:04 AM
Subject: System Bus Adapter Fail
Anyone know this one on an N-Class?
Sounds like time to get ye olde torx screwdriver ...
************* SYSTEM ALERT ************** SYSTEM NAME: uninitialized
DATE: 09/10/2015 TIME: 15:37:35
ALERT LEVEL: 6 = Boot possible, pending failure - action required
REASON FOR ALERT
SOURCE: 8 = I/O
SOURCE DETAIL: 2 = system bus adapter SOURCE ID: 0 PROBLEM DETAIL: 3 = function failure
LEDs: RUN ATTENTION FAULT REMOTE POWER
FLASH FLASH ON ON ON LED State: Boot Failed. Running non-OS code. Non-critical error detected.
Check Chassis and Console Logs for error messages.
0x2000006382001193 000000FF FFFFFF82 - type 4 = Physical Location
0x5800086382001193 00007308 0A0F2523 - type 11 = Timestamp 09/10/2015 15:37:35
A: ack read of this entry - X: Disable all future alert messages Anything else skip redisplay the log entry
->Choice:Timeout!
*****************************************
************* SYSTEM ALERT ************** SYSTEM NAME: uninitialized
DATE: 09/10/2015 TIME: 15:38:07
ALERT LEVEL: 6 = Boot possible, pending failure - action required
REASON FOR ALERT
SOURCE: 8 = I/O
SOURCE DETAIL: 3 = local bus adapter SOURCE ID: FF PROBLEM DETAIL: 6 = configuration error
LEDs: RUN ATTENTION FAULT REMOTE POWER
FLASH FLASH ON ON ON LED State: Boot Failed. Running non-OS code. Non-critical error detected.
Check Chassis and Console Logs for error messages.
0x2000006683FF2164 000101FF FF03FF83 - type 4 = Physical Location
0x5800086683FF2164 00007308 0A0F2607 - type 11 = Timestamp 09/10/2015 15:38:07
A: ack read of this entry - X: Disable all future alert messages Anything else skip redisplay the log entry
->Choice:Timeout!
*****************************************
Main Menu: Enter command or menu > BO
Interact with IPL (Y, N, or Cancel)?> Y
ERROR: A fatal error has occurred- system cannot boot.
Review warning messages in the Information menu.
Boot terminated.
Main Menu: Enter command or menu >
Tracy Johnson
+00 1 757 766-4318 tel
+00 1 757 755-6470 mobile
[log in to unmask]
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|