Barry Durand <[log in to unmask]>
Reply To:
Barry Durand <[log in to unmask]>
Date:
Tue, 3 May 2005 11:21:36 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (39 lines)
We have a customer who is on MPE 6.5, PP4 and ever since installing
power patch 4, it takes a long time to get to a SHUT 6.
:RUN RUNPSMON.PRED.SYS;XL='XL.PRED.SYS,DIAGXL.PRED.SYS';PARM=-65
:STMSHUT.DIAG.SYS
:NSCONTROL STOP
:NETCONTROL STOP;NET=LAN1
:NETCONTROL STOP;NET=LOOP
:NETCONTROL STOP

Everytime they shut down the system,
it hangs after the shut 4 and then they get
the system pin number 22 timed out 5 minutes after the shut 4, then they
finally get part of the shut 5 message, then the shut 6 message.

I believe that part of the problem (if not all of it), is that STM is
not shutting down.   If they do a SHOWPROC right before the shutdown
(after all of the above commands have been issued) there are still
STM processes running:

C152* 1:39.733  WAIT             54   (/usr/sbin/stm/uut/bin/sys/diagmond)
C152  5:19.231  WAIT               401  (/usr/sbin/stm/uut/bin/sys/diaglogd)
C152  0:08.171  WAIT               411  (/usr/sbin/stm/uut/bin/sys/memlogd)

Does anyone have any ideas?

Thank you,

Barry

+------------------------------------------
+ Barry Durand           [log in to unmask]
+ Allegro Consultants    408.252.2330 ext 223
+ http://www.allegro.com
+ Opinions are mine, not my employer's.
+------------------------------------------