On Fri, August 4, 2023 10:11, Craig Lalley wrote:
> James,
> Off hand guess
> SHOWVAR HPPATH
> -Craig
>
On Fri, August 4, 2023 10:12, Ray Legault wrote:
> Look at HPPATH to see what groups you placed in there decades ago! Then
> you have an idea.
>
Thank you both. The problem arose because we are switching to Charon (despite
my early skepticism that such a thing would ever appear). We have a system
LOGON UDC name LOGON which sets all sorts of things, including HPPATH. Well,
Stromasys provides their own LOGON UDC, also named LOGON.
Sooo, one clobbered the other, or rather one has precedence in the catalog.
Our LOGON UDC never executed so HPPATH was never set up as expected. And, as
this was set up originally sometime around 1988 and since it runs invisibly I
had absolutely no recollection whatsoever of this UDC.
Mystery solved.
--
*** e-Mail is NOT a SECURE channel ***
Do NOT transmit sensitive data via e-Mail
Unencrypted messages have no legal claim to privacy
Do NOT open attachments nor follow links sent by e-Mail
James B. Byrne mailto:[log in to unmask]
Harte & Lyne Limited http://www.harte-lyne.ca
9 Brockley Drive vox: +1 905 561 1241
Hamilton, Ontario fax: +1 905 561 0757
Canada L8E 3C3
* To join/leave the list, search archives, change list settings, *