Subject: | |
From: | |
Reply To: | |
Date: | Thu, 29 Aug 1996 10:19:10 -0400 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
I assume you have a system logon UDC command. Add the following command:
SETVAR TZ "EST5EDT"
If you do not have a system logon UDC, set one up. If you need help, please
call.
Leonard Berkowitz
RIA Group (Warren, Gorham & Lamont)
617-292-8349 (EST5EDT, also)
______________________________ Reply Separator _________________________________
Subject: More SETCLOCK / SHOWCLKS Questions
Author: John Hornberger <[log in to unmask]> at Internet-Exchange
Date: 08/29/96 9:51 AM
Dear Listers,
I have come up with still another question regarding the internal
clocks on the HP3000. Using Damian Coffey's suggestion of the
'showclks.pubxl.telesup' command, I found out that my "Time Zone"
variable is not set to any value. See results below:
SHOWCLKS.PUBXL.TELESUP
SHOWCLKS/XL A.10.00
DEBUG/iX B.79.06
HPDEBUG Intrinsic at: fb5.00007258 PROGRAM+$198
PRIV=$3 := $0
*************************************************************
*** ***
*** Greenwich Mean Time : WED, AUG 28, 1996, 5:19 PM ***
*** GMT/MPE offset : -4:00:00 ***
*** MPE System Time : WED, AUG 28, 1996, 1:19 PM ***
*** ***
*************************************************************
**** C Library Information ****
Current value of Time Zone(TZ) variable : NOT ASSIGNED
CTIME function return : Wed Aug 28 13:19:33 1996
How do I set the "TZ" variable to 'EST5EDT' so that I will finally
have my machine keeping time the way it should??
Any help is greatly appreciated!!
- John Hornberger
Sr. Systems Programmer
General Signal Services
|
|
|