:SETCOUNTER OUTSP;BASE=1

This will reset the counter to 1.  You can make this automatic by using the
MAX parameter of the SETCOUNTER command to set a maximum value for spool
file IDs, after which it will cycle back to 1.  It also works for job
numbers.  Use HELP to get more information.

-----Original Message-----
From: [log in to unmask] [mailto:[log in to unmask]]
Sent: Monday, December 31, 2001 8:58 AM
To: [log in to unmask]
Subject: Renumber Spoolfiles


Our tech support is on extended leave and we want to start the
spoolnumbers over - they're at 190,980 currently and we're all getting
tired of having to type in a six byte number to access them.
Can anyone tell us how to do this?
Thanks,

**********
Posted from www.3kworld.com