Stan Sieler <[log in to unmask]>
Reply To:
Stan Sieler <[log in to unmask]>
Date:
Tue, 7 Oct 1997 11:51:51 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (77 lines)
Srivathsa asks:

> I am working on HP Sockets.
>
> The source code for this product is available in MPE 4.0 which is obsolate now.
> So I have to build the product in MPE 5.0 and test it at the earliest.
>
> The problem that I have is that the compilation of MPE 4.0 source codes on MPE 5.0
> goes through well,  but the product doesn't run at all. When  the MPE 4.0 product
> executable is put in the appropriate groups/account in MPE 5.0, it runs perfectly.
> The communicator for MPE 5.0 says that any application written for MPE XL works
> fine with MPE/iX without any change. I am attaching herewith a copy of the spool
> output when I start running the product. Can you please tell me what the problem
> could be?

As the resident HP Sockets expert ...
nah, I can't say that with a straight face :)


I have several comments/suggestions for you...

1) My understanding is that HP Sockets (for the 3000) is supposed to be compiled
   on HP-UX, and then *linked* on a 3000.  If true, then by changing the build
   process to compile on the 3000, you're getting different compilers, and
   introducing new variables into the equation.  (Perchance, were you unable
   to compile on the 9000 because of 10.x changes?)

2) Can you provide the following to help diagnose the problem:

   a) Prior to running the program, enter the command:

         :SETDUMP

   b) when the program aborts, you'll be put into Debug, please enter:

         dc SpGet_Next_Msg, #40

   and email the results.

thanks!

> Thanking you in advance,
>
> With regards,
> Srivathsa
>
>
> =================================================================================
> JOB STARTSMD,MGR.HPSKTS,PUB.
>  Priority = CS; Inpri = 8; Time = UNLIMITED seconds.
>  Job number = #j6.
>  TUE, OCT  7, 1997,  2:27 PM.
>  HP3000  Release: C.50.00   User Version: G.02.06
>  MPE/iX  HP31900 B.79.06  Copyright Hewlett-Packard 1987.
>  All rights reserved.
>  STREAMED BY MGR.HPSKTS (#S8) ON LDEV# 17
>     STREAM DATE:   TUE, OCT  7, 1997,  2:27 PM
>  :run smd.pub.hpskts
>
>
>  **** Data memory protection trap (TRAPS 68).
>
>  ABORT: SMD.PUB.HPSKTS
>  NM PROG  5f8.0004d778 SpGet_Next_Msg+$70
>
>
>  Program terminated in an error state. (CIERR 976)
>  REMAINDER OF JOB FLUSHED.
>  CPU sec. = 1.  elapsed min. = 1.  TUE, OCT  7, 1997,  2:27 PM.
>  =================================================================================
>


--
Stan Sieler                                          [log in to unmask]
                                     http://www.allegro.com/sieler.html