Hello,
according to the intrinsic reference manual:
The process is not created and the pin parameter is returned
unmodified if one of the following conditions exist:
- The program file of the creating process does not have PH capability
- a required parameter (formal desig or pin) is omitted
- a reference parameter is not within the required range.
So if you don't wont to check the condition code, set the pin
parameter to zero before calling CREATE. This should work.
Mit freundlichen Grüßen / Best regards
Günter Kuhn
SSD IT Consulting GmbH
Greppen, Switzerland
----- Original Message -----
From: "Satheesh Kumar" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Wednesday, April 21, 2004 12:52 PM
Subject: Information on MPE intrisic "CREATE" Condition Codes
> We are facing a problem while executing CREATE intrinsic.
>
> The CREATE intrinsic always returns a Condtion Code value less than ZERO.
> We are getting the PIN value of the created process as -1234.
>
> Our question is why the Condition Code is always giving a value less than
> zero even a process is created with a PIN value -1234.
>
> Normally if the procees is not created the PIN value should be ZERO.
>
> Here process is created but Condition Code is not equal to zero.
>
> Do we have to set up any special enviroment variables to make CREATE
> intrinsic work ?
>
> Please help us in this issue.
>
> * To join/leave the list, search archives, change list settings, *