John,
Do you use StreamX from Vesoft? If yes, we had the following system abort
on 6.5 pp2 + patches
System Abort 1458 from Subsystem 102
Secondary Status: Info=-300, Subsys 107
System Halt 7, $05B2
The system abort occurred when there is a typo in the job card and using
StreamX. You will get the error message "Nil ccb pointer - internal error.
(CIERR 9016)" when streaming the job with the typo. This corrupts the Job
Master Table and the next time a process transverses this table, a system
abort will occur. I think the command SHOWJOB will transverse this table.
The problem was introduced with patch mpelxv2b, witch is on pp3 for 6.5.
You may want to call the RC to see if the problem exist on 7.0
Hope this helps.
Randy Breitfelder
Nielsen Media Research
-----Original Message-----
From: John Penney [mailto:[log in to unmask]]
Sent: Tuesday, February 05, 2002 10:53 AM
To: [log in to unmask]
Subject: [HP3000-L] System Abort 1458
Good Morning Gentle Listers:
I've gotten 2 of these in the past 4 weeks:
System Abort 1458 from Subsystem 102
Secondary Status: Info=-31, Subsys 107
System Halt 7, $05B2
FLT 0105,B807,02B2,DEAD
MPE/iX Error Message Manual states:
"A critical process is being terminated due to a trap..."
Many thanks for any information.
Regards
Would anybody care to suggest what I should look for to apply a solution.
Running 7.0 Powerpatch 1 on a 929 KS020 with 1.2GB.
John M Penney
Systems Programmer
Production Services
Information Services Department
Pierce County
Tacoma, WA
253-798-6215
253-798-6680 Fax
[log in to unmask]
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|