There is a JCW you can set to:
SETJCW STREAMXNONEST 1
50:50 chance that may help, otherwise you can set it to zero.
On Tue, Sep 12, 2017 at 1:45 PM, John Sommer <[log in to unmask]>
wrote:
> Hi All,
>
>
> We use VESoft's MPEX to help manage the system.
> I have noticed that the STDLIST has a strange statement.
> It is...."{}{}{} strnest !JOB..."
>
>
> It is acting like it is streaming a job that it was supposed to ignore.
> It should have ran the job if HPDAY=6, however HPDAY was 1.
>
>
>
> 98 !# FRIDAY
> 99 !IF HPDAY = 6 THEN
> 100 !# Comment
> 101 !STREAM NRX01BB.JOB;DAY=FRIDAY;JOBQ=CLNIGHT
> 102 !#STREAM COREEXP.JOB;DAY=SATURDAY;JOBQ=CLNIGHT
> 103 !ENDIF
> 104 !
>
>
>
> The result is...
>
>
> {}{}{} strnest !JOB NRX01BB,MGR.XXXX,SUB;&
> !INPRI=8;OUTCLASS=LP,01
>
>
> I have searched the MPEX help for "strnest" and found nothing.
> No mention of it on the Internet either.
> I also scanned a PDF version of the MPEX manual for "strnest" and nothing
> there either.
>
>
> Has anyone seen that before?
> If so, any idea what causes it?
>
>
> Thanks,
> John
>
>
>
>
>
>
>
>
>
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
>
--
Tracy Johnson
Old fashioned text games hosted below:
http://empire.openmpe.com/empire/
BT
NNNN
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|