Hi,

Mike Reaser (I think) wrote:
>: "Pure MPE" gives me the dreaded "Unknown command name.
>: (CIERR 975)" on the :GREP command.
>:
>: Mayhaps you were thinking of doing these under the Posix shell?


Erik Vistica responded:
>Insert /SYS/HPBIN in front of the grep command.
>
>/SYS/HPBIN/GREP 'SM X'
>
>Or qualify it with GREP.HPBIN.SYS.
>
>GREP.HPBIN.SYS 'SM X'


Or put /SYS/HPBIN in the HPPATH variable (like DenKor's machines):

SETVAR HPPATH, "XEQ.SYS," + HPPATH + ",HPBIN.SYS"

Cheers!

 +-------------------------------------------------------------------+
  My mind is my own, as are my ideas and opinions.
  My heart, body, and soul, however, all belong to others.       Tim.
 +-------------------------------------------------------------------+
  Tim Ericson            tericson      DenKor Dental Management Corp.
  Sr. Systems Analyst     at denkor    503-526-4440 (my direct number)
    (& Systems Manager)     dot com         http://www.denkor.com
  Programming HP3000s since 1983!      Quality dental care since 1970!
 +-------------------------------------------------------------------+
  UDCs and Command Files:  http://www.denkor.com/hp3000/command_files
 +-------------------------------------------------------------------+