Gary Groves <[log in to unmask]>
Reply To:
Gary Groves <[log in to unmask]>
Date:
Thu, 14 Oct 1999 16:33:42 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (134 lines)
OR....

Output from Suprtool as PRN file and have the COBOL program parse the field.
If the field is too large for the COBOL field to handle then handle the
overflow condition in the program as an exception.

> -----Original Message-----
> From: Eben Yong [SMTP:[log in to unmask]]
> Sent: Thursday, October 14, 1999 3:34 PM
> To:   [log in to unmask]
> Subject:      Re: HOW TO DEFINE P28 field in COBOL WORKING-STORAGE?
>
> Thank you all for input.  I still need help, here... I tried the
> following,
> per suggestions on the listserv:
>
>  *   fd  IN-FILE.
> +1   01  IN-RECORD.
> +2       05  IN-A                      pic x(6).
> +3       05  IN-TOTAL                  pic s9(27) comp-3.
>
> but when I tried to compile it using  COB85XLK COBTEST,COBTEST1,$NULL  I
> received this:
>
> PAGE 0001  COBOL II/iX HP31500A.04.19  [85] Copyright Hewlett-Packard CO.
> 1987
>
>
> LINE #   SEQ # COL ERROR SEV            TEXT
> --------------------------------------------------------------------------
> --
> --
>  00030  002022  46  122  Q  MORE THAN 18 DIGITS IN A NUMERIC PICTURE.
>
> 0 ERROR(s), 1 QUESTIONABLE, 0 WARNING(s)
>
>     DATA AREA IS      6FC BYTES.
>     CPU TIME = 0:00:00.  WALL TIME = 0:00:00.
> End Run
> END OF COMPILE
> HP Link Editor/iX (HP30315A.05.26) Copyright Hewlett-Packard Co 1986
>
> LinkEd> link ;to=COBTEST1
>
> END OF LINK
>
>
> And then, when I tried run the program:
>
> RUN COBTEST1
>
> Filename: INFILE
> File status is 39
> File's fixed attributes differ from program [39] RECORD SIZE (COBERR 648
> )
> Program file: COBTEST1.EBEN.AIHBETA
> END OF FILE  (FSERR 0)
>
> +-F-I-L-E---I-N-F-O-R-M-A-T-I-O-N---D-I-S-P-L-A-Y+
> !  FILE NAME IS Z1.EBEN.AIHBETA                  !
> !  FOPTIONS: SYS,ASCII,FORMAL,F,NOCCTL,FEQ       !
> !            NOLABEL                             !
> !  AOPTIONS: INPUT,NOMR,NOLOCK,DEF,BUF,NOMULTI   !
> !            WAIT,NOCOPY                         !
> !  DEVICE TYPE: 3      DEVICE SUBTYPE: 8         !
> !  LDEV: 40       DRT: 8         UNIT: 0         !
> !  RECORD SIZE: 20     BLOCK SIZE: 1280  (BYTES) !
> !  EXTENT SIZE: 20     MAX EXTENTS: 1            !
> !  RECPTR: 0           RECLIMIT: 28              !
> !  LOGCOUNT: 0            PHYSCOUNT: 0           !
> !  EOF AT: 28          LABEL ADDR: %00000000000  !
> !  FILE CODE: 1084     ULABELS: 12               !
> !  FILE OWNER: MGR.AIHBETA                       !
> !  PHYSICAL STATUS: 0000000000000000             !
> !  ERROR NUMBER: 0     RESIDUE: 0                !
> !  BLOCK NUMBER: 0            NUMREC: 64         !
> +------------------------------------------------+
> **** COB_QUIT 648 ****
>
> ABORT: COBTEST1.EBEN.AIHBETA
> NM SYS   a.00aa1288 dbg_abort_trace+$24
> NM USER  18c.00f16394 COB_QUIT+$b8
> NM PROG  3d1.0000599c _start+$12c
> Program terminated in an error state. (CIERR 976)
> End Run
>
> -----Original Message-----
> From: John Zoltak [mailto:[log in to unmask]]
> Sent: Thursday, October 14, 1999 7:55 AM
> To: [log in to unmask]; [log in to unmask]
> Subject: RE: [HP3000-L] HOW TO DEFINE P28 field in COBOL
> WORKING-STORAGE?
>
>
> Eben,
>
> 05 in-total pic s9(27) comp-3. This assumes decimal place the the end. If
> you're using dollars and cents then it would be pic s9(25)v9(2) comp-3.
>
> John Zoltak
> North American Mfg Co
> Cleveland Ohio
>
> > -----Original Message-----
> > From: Eben Yong [mailto:[log in to unmask]]
> > Sent: Thursday, October 14, 1999 10:35 AM
> > To: [log in to unmask]
> > Subject: [HP3000-L] HOW TO DEFINE P28 field in COBOL WORKING-STORAGE?
> >
> >
> > Hi folks,
> >
> > Here's the SUPRTOOL file layout:
> >
> >     File: Z1.EBEN.AIHBETA     (SD Version B.00.00)
> >        Entry:                     Offset
> >           A                    X6      1
> >           ST-TOTAL-1           P28     7
> >     Limit: 28  EOF: 28  Entry Length: 20  Blocking: 64
> >
> > how do I define the ST-TOTAL-1 field in the COBOL program?
> >
> > +7   file-control.
> > +8       select     IN-FILE         assign to "INFILE".
> > +9       select     OUT-FILE        assign to "OUTFILE".
> > 10   data                              division.
> > 11   file                              section.
> > 12   fd  IN-FILE.
> > 13   01  IN-RECORD.
> > 14       05  IN-A                      pic x(6).
> > 15       05  IN-TOTAL                  pic ?????????.
> > 16
> >