Subject: | |
From: | |
Reply To: | |
Date: | Thu, 14 Sep 1995 15:55:54 PDT |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
>[BUG report]
>
>The BASIC/V intriniscs for SNA/IMF have problems on MPE/iX 5.0 (push release
>including powerpatch C.50.02).
>
>The BOPEN3270(...) call fails with error code = 26 which means something
>about a parameter address out of bounds. I don't know yet if any, or all,
>of the other BASIC/V intriniscs also have errors or not.
>
>Please note that HPRC was able to establish a PASSTHRU connection so they
>thought that IMF was OK. This problem has been esclated within the HPRC
>so lets see how soon it is resolved, the 'lab' is in India.
>
>[end BUG report]
==========================================================================
And the solution is:
The set of intrinsics, without a leading B, were upgraded to support BASIC/V
as of release MPE/XL 2.2 but it was never documented.
In release MPE/iX 5.0 HP decided to drop the B..., BASIC/V intrinsics, but it
was never documented in the SNA/IMF Programmers Reference Manual.
Our client is testing new versions of the interface pgms on release
MPE/iX 4.0. Yes the client had to backout the 5.0 upgrade because the
interface is mission critical.
Out next step is to test the interface pgms on a loaner machine running 5.0,
probably next week.
More when I know more.
######################################################################
# Phil Wehrman ADAC HealthCare Information Systems #
# [log in to unmask] 540 Alder Drive #
# Pgmr Analyst/System Manager Milpitas, CA 95035 #
# Ph # (408) 321-9100 x3025 FAX # (408) 577-1707 #
######################################################################
|
|
|