Stan Sieler wrote:

> Rick writes:
> > We are currently running a 959KS and yes the system does need to be
> > re-booted to
> > reset the modem. However, I do have a workaround that we use courtesy of
> > HP.
>
> You can find out about the "sections" of a sysdiag diagnostic by
> doing:
>
>    sysdiag
>    help consolan section
>
> I think...I can't duplicate because our 10.01 system is being
> snitty about running sysdiag, and
>
> ARGH!!!
>
> On 10.20, HP has replaced sysdiag with "Support Tools Manager",
> (stm / xstm / cstm)
> which is sigificantly different from sysdiag, and (at least
> for everything I've tried to do) SIGNFICANTLY worse.
>
> So...I got info about consolan from MPE's sysdiag (essentially the
> same set of programs!):
>
>    :sysdiag
>    DUI>help consolan section
>
>    Section 2 - Reset
>        Depending on the step selected, resets either the entire Console/LAN card,
>        the LAN port, or a specified serial port, as well as the associated driver
>        software.
>
> ...
>    Section 16 - Interactive Access
>        This section provides a more convenient means of accessing all the other
>        sections and steps in Consolan.  It is useful in the event the user desires
>        to run more than one section before returning to the "DUI>" prompt, but
>        does not wish to be forced to specify every section and step in the initial
>        run string from the "DUI>" prompt.
>
> ...
>
> So, I thought...let's run the interactive part...
>
>    DUI >run consolan;section=16
>    *** WARNING:  YOU NEED TO HAVE A self-maintainer/channel LICENSE TO
>                  RUN THIS PROGRAM.
>
>    DUI >exit
>
> Sh*t.  Altogether now:  THANK YOU RICH SEVCIK!
>
> NOTE: you'll need a password to run parts of sysdiag on your HP-UX machine,
> as of 9.x (forgot what version added the password restriction).
>
> --
> Stan Sieler                                          [log in to unmask]
>                                      http://www.allegro.com/sieler.html


OH. Bitten by the old 'need a password now but never needed one before' gotcha.

I ran the consolan with section=16 and received the following error..

DUI >CONSOLAN;SECTION=16
***************************************************************************
******                                                               ******
******              Consolan Device Adapter Diagnostic               ******
******                                                               ******
******        (c) Copyright Hewlett-Packard Co. 1986 - 1994          ******
******                     All Rights Reserved.                      ******
******                                                               ******
******  This program may only be used by HP support personnel and    ******
******  those customers with the appropriate Class license or        ******
******  Node license for systems specified by the license.  HP       ******
******  shall not be liable for any damages resulting from misuse    ******
******  or unauthorized use of this program.  This program           ******
******  remains the property of HP.                                  ******
******                                                               ******
******                        Version A.00.02                        ******
******                                                               ******
***************************************************************************


Welcome, Today is THU, MAR  5, 1998 at  2:08 PM

*** NO DEVICE WAS SELECTED (DSSERR 1000)

    Do you wish to continue (Y/N) [N]?Y

*** CANNOT RUN SECTION 16 : A DEVICE TO TEST WAS NOT SPECIFIED
IN THE RUN COMMAND AS REQUIRED BY THE SECTION.  (DSSERR 1805)
*** WARNING -- NO VALID SECTIONS(STEPS) WERE SPECIFIED OR REQUIRED ACCESS/TEST
*** MODES COULD NOT BE OBTAINED.  (CONSOLANWARN 6007)
*** Valid sections(steps) are 2(21), 2(22), 2(23), 3, 4, 5(51), 5(52), 6,
*** 7(71), 7(72), 8, 9, 10, 11, 12, 13, 14, 15, 16, 17.

*** The above message was printed on THU, MAR  5, 1998,  2:08 PM.

CONSOLAN has terminated
DUI >

It looks like, according to their statement you don't need any other parms with
section 16, but when do
you believe what you read....

Rick Clark
P/A for WW&R
Cleveland, Ohio