HP3000-L Archives

November 2002, Week 3

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Leonard S. Berkowitz" <[log in to unmask]>
Reply To:
Date:
Tue, 19 Nov 2002 13:35:17 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (22 lines)
After we installed MPE/iX 6.5 Express 2 with the Expanded TurboImage
limits, we created several new [dummy] datasets to reach into the low
200's. No problems there. However, we did not check all of the third-party
products. Now that we have a production need, we found that two products of
which one was critical to the process were not > 199 datasets ready. We are
now in the process of upgrading those products.

I am carefully not mentioning the names of the vendors as we were laggard
in installing software upgrades that we had already received, and both
vendors responded promptly and appropriately to our needs. (I would be
happy to identify the products privately, if asked.)
--
Leonard S. Berkowitz
Perot Health Care Systems
(Harvard Pilgrim Health Care account)
voice: 617-509-1212
fax: 617-509-1955
pager: 781-226-2431