Typo - ALTSET should be ALTSEC.
At 05:12 PM 10/12/2004, Stuart Diamond , [log in to unmask] wrote:
>Use ALTSEC to set an ACD on QUERY.PUB.SYS to lock the user out.
>
>:ALTSET QUERY;NEWACD=(NONE:<fully qualified name>)
>
>At 05:13 PM 10/12/2004, Stuart Diamond wrote:
>>Nice try, but the user can just type run query.pub.sys. Anyone have a
>>real solution?
>>
>>Stu Diamond
>>HP Systems Manager
>>Hours: Monday 7:30 AM - 6:00 PM
>> Tues-Thurs 10:30 AM - 9:00 PM
>>
>>Phone: 1 631 738-5521
>>Beeper: 1 877 409-1239
>>
>>Symbol. The Enterprise Mobility Company. (TM)
>>
>>
>> >>> "Wyell Grunwald" <[log in to unmask]> 10/12/04 05:11PM >>>
>>certainly - set up a UDC that is invoked at logon named QUERY, and have
>>it do a ECHO you are not allowed to use QUERY.
>>
>> >>> Stuart Diamond <[log in to unmask]> Tuesday, October 12, 2004
>>5:06:05 PM >>>
>>Is there a way to lock out a specific user so that they can not get
>>into Query??
>>
>>Stu Diamond
>>HP Systems Manager
>>Hours: Monday 7:30 AM - 6:00 PM
>> Tues-Thurs 10:30 AM - 9:00 PM
>>
>>Phone: 1 631 738-5521
>>Beeper: 1 877 409-1239
>>
>>Symbol. The Enterprise Mobility Company. (TM)
>>
>>
>>
>>________________________________________________________________________
>>This email has been scanned for computer viruses.
>>
>>* To join/leave the list, search archives, change list settings, *
>>* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
>>
>>
>>IMPORTANT WARNING: The information in this message (and the documents
>>attached to it, if any) is confidential and may be legally privileged. It
>>is intended solely for the addressee. Access to this message by anyone
>>else is unauthorized. If you are not the intended recipient, any
>>disclosure, copying, distribution or any action taken, or omitted to be
>>taken, in reliance on it is prohibited and may be unlawful. If you have
>>received this message in error, please delete all electronic copies of
>>this message (and the documents attached to it, if any), destroy any hard
>>copies you may have created and notify me immediately by replying to this
>>email. Thank you.
>>
>>________________________________________________________________________
>>This email has been scanned for computer viruses.
>>
>>
>>
>>________________________________________________________________________
>>This email has been scanned for computer viruses.
>>
>>* To join/leave the list, search archives, change list settings, *
>>* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
>
>--
>Tom Brandt
>Northtech Systems, Inc.
>130 S. 1st Street, Suite 220
>Ann Arbor, MI 48104-1343
>http://www.northtech.com/
--
Tom Brandt
Northtech Systems, Inc.
130 S. 1st Street, Suite 220
Ann Arbor, MI 48104-1343
http://www.northtech.com/
* To join/leave the list, search archives, change list settings, *