HP3000-L Archives

July 2005, Week 2

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Johnson, Tracy" <[log in to unmask]>
Reply To:
Johnson, Tracy
Date:
Thu, 14 Jul 2005 12:45:53 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (56 lines)
If you get that error, at least Telnet is working.

In addition to raising the limits above zero, lower the jobfence with
the JOBFENCE command to 7 or below.

Tracy Johnson
Measurement Specialties, Inc. 

BT







NNNN


> -----Original Message-----
> From: HP-3000 Systems Discussion 
> [mailto:[log in to unmask]] On Behalf Of Peter Smithson
> Sent: Thursday, July 14, 2005 12:33 PM
> To: [log in to unmask]
> Subject: [HP3000-L] Can't telnet to our hp3000
> 
> 
> Hi,
> 
> Background  - I know virtually nothing about hp3000 network 
> or hardware problems.  Our MPE test system stopped working a 
> few months ago and I've finally got round to having a look.
> 
> I can boot it up and type commands on the console.
> I can ping it from my PC.
> When I telnet to it from my PC I get the message -
> "Can't initiate new sessions now. (CIERR 80)"
> I think I've had that before and I fixed it with a LIMIT 
> command but I'm not sure that it's the same problem as now I 
> can't ping it and I can't even type commands at the console - 
> it just hangs.  I can hit ctrl-B and re-boot it but that's about all.
> 
> It's as if network activity breaks it or something - I've no 
> idea really. Any suggestions?
> 
> Thanks.
> 
> Peter
> 
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
> 

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2