HP3000-L Archives

December 1996, Week 5

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Therm-O-Link <[log in to unmask]>
Reply To:
Therm-O-Link <[log in to unmask]>
Date:
Tue, 31 Dec 1996 13:33:47 EST
Content-Type:
text/plain
Parts/Attachments:
text/plain (31 lines)
On Fri, 27 Dec 1996 23:10:51 GMT, Nigel Campbell <[log in to unmask]>
writes:

>Therm-O-Link ([log in to unmask]) wrote:
>: On Thu, 26 Dec 1996 09:23:36, "Paul D. Christensen - PC Enterprises"
>: <[log in to unmask]> writes:
>
>: >Minor correction on the previous writers point.  QUIZ does not require
>: >it's "own" data dictionary, but uses HP's dictionary/3000 product
>: >that can be used with BRW, Inform, and can create COBOL copylibs.
>
>: Maybe the later versions do, but my version (5.06.C) requires its
>: own DD.  Like I said, it's been awhile since we used QUIZ to create any
>: new reports, but we do use it for some production reports in a third-
>: party application.  Guess I should have qualified my response as to the
>: version we are using.
>
>We added support for D/3000 around PowerHouse 4.00.

Okay, let me see if I can clarify this a bit more:

We don't have D/3000.  We do have to run QDD to generate a QSCHEMAC file
in order for QUIZ to work.  To me, that means that QUIZ has its own DD.
Now, if it can use D/3000, that's great!  But, you don't need D/3000 in
order to run QUIZ, do you?

Jim Phillips (Not a QUIZ expert)        Manager of Information Systems
E-Mail: [log in to unmask]      Therm-O-Link, Inc.
Phone: (330) 527-2124                   P. O. Box 285
  Fax: (330) 527-2123                   Garrettsville, Ohio  44231