Subject: | |
From: | |
Reply To: | |
Date: | Tue, 27 Mar 2007 15:29:40 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Robert:
I the program can be slightly modified, then I would suggest creating a
message file as a conduit to the application. The program would do a
read of the message file with the nowait option every once and awhile.
If the application encounters a keyword indicating a new spoolfile, then
the program would close the spoolfile and reopen it.
An alternate method would involve the application being modified to
close and open the file at a particular day and time during the week.
Olav Kappert
IOMIT International
(HP Application Design and Software Development Specialist)
Consultant.
Robert Holtz wrote:
>We have out 911 interface running on our HP3000 24x7. Once a week, we
>abort the application to close out the spool file that the application
>generates. Is there a way to keep the application running and redirect
>the output to a new spool file?
>
>We are running MPE 7.0 PP2 and this is on an N-Class e3000 system.
>
>
>
>Thanks,
>
>Robert Holtz
>
>Senior Information Technology Systems Specialist
>
>Phoenix Police Department
>
>
>* To join/leave the list, search archives, change list settings, *