HP3000-L Archives

January 2012, Week 2

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Keven Miller <[log in to unmask]>
Reply To:
Keven Miller <[log in to unmask]>
Date:
Tue, 10 Jan 2012 08:01:38 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (35 lines)
Guess I didn't respond soon enough.


>> Pstudio says:
>> MPE/iX RPM error 11 calling "RPMCREATE"
>> PROGRAM ACCESS ERROR.

Looking up error 11 in
NS 3000/iX Error Messages Ref Man.
Chapter 9 Remote Process Management

MESSAGE: PROGRAM ACCESS ERROR.
11 CAUSE: The program to be created by an RPMCREATE could not be
accessed. This may be due to one of the following reasons:
1. The program file is secured against access from the login user and
account.
2. The program file has a lockword that was not specified in progname.
3. The program name in progname is not syntactically correct
ACTION: Depending on the cause:
1. Change the program file’s security or the login user and account to
allow Execute access to the program.
2. Insert the program file’s lockword into the progname parameter. The
syntax is:
progname/lockword[.acct][,group]]
3. Correct the syntax of the progname


Not sure what the  -7  code refers to.

(For RPM and other network (NS) errors, keep this manual handy)
Keven Miller

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2