Subject: | |
From: | |
Reply To: | |
Date: | Wed, 3 Feb 1999 13:29:28 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
On Wednesday, February 03, 1999 1:00 PM, Dave Dement [SMTP:[log in to unmask]] wrote:
| When I do a SHOWVAR @ command at the : prompt, I notice near the bottom
| of the list that there is an entry
|
| HPTYPEAHEAD: False
|
| How do I get that to change to true? It would be an almots invaluable
| asset.
|
| Nathan Buck
At the MPE/iX prompt type :
SETVAR HPTYPEAHEAD,TRUE (or FALSE, depending on need)
or
SETVAR HPTYPEAHEAD TRUE
Hope this helps....I toggle this variable programatically using cobol and the
'command' intrinsic.
--------------------------------------------------------------------
David Burney Summit Racing Equipment
[log in to unmask] 330.630.0270 x. 221
------
Before criticizing someone, walk a mile in their shoes.
Then, when you do criticize them, you will be a mile
away and have their shoes. - Jack Handey
------
All opinions expressed herein are my own and reflect,
in no way, those of my employer.
---------------------------------------------------------------------
|
|
|