Subject: | |
From: | |
Reply To: | Miller, Keven |
Date: | Thu, 22 Jun 2006 16:54:44 -0600 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Kent Wallace wrote:
> We are in the process of migrating to Micro focus COBOL and ORACLE on
> HP-UX. Does someone know if the functions
>
> INTERGER-OF-DATE
>
> CURRENT-DATE
>
> And others work in Micro Focus COBOL as they did in HP3000 COBOL?
>
Sorry, I don't have access to an HPUX at the moment.
[linux] kevsrc/test$ ll datechk*
-rw-r--r-- 1 xport bitech 699 2006-06-22 16:40 datechk.cbl
[linux] kevsrc/test$ cat datechk.cbl
****************************************************************
IDENTIFICATION DIVISION.
ENVIRONMENT DIVISION.
DATA DIVISION.
WORKING-STORAGE SECTION.
01 STR PIC X(30) VALUE SPACES.
01 IDAT PIC S9(9) VALUE 20060622.
01 RTV PIC S9(9) VALUE 0.
*****************************************************************
PROCEDURE DIVISION.
MOVE FUNCTION CURRENT-DATE TO STR.
DISPLAY "CD=", STR.
MOVE FUNCTION INTEGER-OF-DATE ( IDAT ) TO RTV.
DISPLAY "ID=", RTV.
STOP RUN.
****************************************************************
[linux] kevsrc/test$ make datechk
Cobol datechk
cob -xg -o datechk datechk.cbl 2> datechk.err -L/opt/lib/cobol/lib -lcobcrtn -lcobrts -lcobmisc
-lcobscreen
[linux] kevsrc/test$ datechk
CD=2006062216442105-0600
ID=000148096+
[linux] kevsrc/test$
Keven
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|
|
|