HP3000-L Archives

November 2011, Week 1

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Gilles Schipper <[log in to unmask]>
Reply To:
Gilles Schipper <[log in to unmask]>
Date:
Sun, 6 Nov 2011 22:42:33 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (69 lines)
Those aren't ldev's that cstm is showing - they're simply numerical instances.

The scsi address of ldev 7 is defintely 0 - as shown by sysgen and cstm.


At 10:33 PM 2011-11-06, John Pitman wrote:
>On one of our 959s, sysgen for tape drive shows:
>
>      io> ldev 7
>LDEV:     7  DEVNAME:                    OUTDEV:        0   MODE:        R
>    ID: HPC1537A                           RSIZE:       128   DEVTYPE: TAPE
>  PATH: 10/4/20.0.0                        MPETYPE:      24   MPESUBTYPE:  7
>CLASS: TAPE
>
>But cstm->map shows:-
>
>     1  10                   Bus Adapter (580)
>     2  10/4                 Bus Adapter (500)
>     3  10/4/0               NIO LAN/Console Interface
>     4  10/4/16              100 BaseT LAN Interface (
>     5  10/4/20              NIO SCSI Interface (5)
>     6  10/4/20.0.0          SCSI Tape (HPC1537A)
>     7  10/4/20.2            Unknown ()
>     8  10/4/20.8.0          Unknown ()
>     9  10/4/20.9.0          Unknown ()
>    10  10/4/24              NIO Fast/Wide SCSI Interf
>    11  10/4/24.5.0          SCSI Disk (SEAGATEST39175
>    12  10/4/24.6.0          SCSI Disk (SEAGATEST39175
>
>Does this mean the SCSI address of the tape drive is 0, or 2 ? the 0
>addr shows on ldev 6, but 2 on ldev 7 ????
>
>I suspect the devnums on the left in cstm are wrong, as they list
>the discs at 11 and 12, not 1 and 2.
>Unfortunately the people replacing the dead dds3 drive are not
>famous for their knowledge of mpe, so I am trying to ensure they get
>it right first time. I hope just telling them to configure all dip
>switches same as old unit will work for us.
>
>Regards,
>
>John Pitman
>
>
>________________________________
>CAUTION: This message may contain privileged and confidential
>information intended only for the use of the addressee named above.
>If you are not the intended recipient of this message you are hereby
>notified that any use, dissemination, distribution or reproduction
>of this message is prohibited. If you have received this message in
>error please notify RYCO Hydraulics Pty. Ltd. immediately. Any views
>expressed in this message are those of the individual sender and may
>not necessarily reflect the views of RYCO Hydraulics Pty. Ltd.
>
>* To join/leave the list, search archives, change list settings, *
>* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

-------------------------------------------------------------------------------------------------
Gilles Schipper
GSA Inc.
HP System Administration Specialists
300 John Street, Box 87651   Thornhill, ON Canada L3T 7R4
Tel: 416.702.7900
email:  [log in to unmask]  web: http://www.gsainc.com
-------------------------------------------------------------------------------------------------

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2