HP3000-L Archives

June 1997, Week 1

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Gilles Schipper <[log in to unmask]>
Reply To:
Gilles Schipper <[log in to unmask]>
Date:
Sun, 1 Jun 1997 11:09:12 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (53 lines)
>"Ray" <[log in to unmask]> wrote:
>I have a third party terminal server (a Lantronix MSS1) which I am trying
>to use to connect a dumb terminal to my mpe/ix system over a NT 4.0 LAN.
>The terminal server is connected to my 10-base-t hub but I cannot get a
>connection. I have PC's with network cards connected this way, running an
>emulator, which connect with no problem.
>

>To what software running on the mpe/ix do the emulators running on the
>PCs connect?   Its obvious that the MSS1 is attempting to connect to
>some other service on the HP3000.  The MSS1 documentation (on CD) should
>indicate what services need to be running on the host, most likely a
>telnet daemon of some kind.
>
>I can ping from the terminal server to the mpe system and get a response.
>
>Does any body have any sugggestions.
>
As long as you are running O/S version MPE/iX 5.5, with at least powerpatch
1, you can telnet to your HP3000 via the HP3000-included telnet server
software.

To start the telnet server software, you need to:

1. log-on as MANAGER.SYS and copy incnfsmp.net,inetdcnf.net
2. modify inetdcnf.net.sys to remove the #'s, which serve to comment out
the lines, from the lines containing telnet. (near the end of the file).
3. copy servsamp.net,services.net
4. NEWLINK /etc/inetd.conf,/SYS/NET/INETDCNF
5. NEWLINK /etc/services,/SYS/NET/SERVICES

These above 5 items are performed once.

Then, to start the telnet server, stream JINETD.NET.SYS. This will launch a
job will runs at all times.  You can simply abort the job to bring down the
telnet server.

Now you should be able to connect to the HP3000 via this Lantronix box.

If you are not running MPE/iX 5.5, you need to utilize some DTC hardware
(and accompanying PC software) alternatives to be able to use incoming
telnet.

The software alternative is more cost-effective.
---------------------------------------------------------------------------
Gilles Schipper
GSA Inc.
HP3000 & HP9000 System Administration Specialists
300 John Street, Box 87651   Thornhill, ON Canada L3T 7R4
Voice: 905.889.3000     Fax: 905.889.3001
Internet:  [log in to unmask]  Compuserve: 71203,474
---------------------------------------------------------------------------