HP3000-L Archives

February 1995, Week 1

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Robert Meissner <[log in to unmask]>
Reply To:
Robert Meissner <[log in to unmask]>
Date:
Fri, 3 Feb 1995 21:06:18 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (37 lines)
I use a very simple method to do call detail recording on my HP3000.
 
I connected the output printer port (log device) on my MITEL telephone
switch an HP3000 DTC serial port.  I used only pins 2 and 7 (Receive data
and Signal ground).  Ross Scrogs taught me this-  if you use the Send pin
(3) you may send an XOFF and hang up the phone system- I would rathe
loose data.  (I may be wrong on pins 2 & 3 they may be reversed)  I then
run FCOPY to log the data comeing in from the PBX to a file.  It now is
very simple to produce all sorts of reports.
 
If you want the full details, I could send them to you.  My phone is FAX
is 215-643-6960 -  Att: Bob Meissner.  I dont check my Internet to often-
I get sucked into reading all the mail.
 
On Thu, 26 Jan 1995, Phil ESGUERRA wrote:
 
> Hello again!
>
> We're looking for a TELEPHONE ACCOUNTING SOFTWARE that runs in the
> HP3000. I know that there are some out there, for I saw their ads
> at one time.
>
> This software will be installed in the HP3000, which is connected
> to the PBX. We want to be able to create reports out of the call records
> created. The reports will show telephone usage, by extension, how long
> the call took, the called number, and the phone charges, among others.
>
> If you are using, or know of a package, similar to the one described,
> please e-mail me. If you are currently using one, please relay your
> experiences, too.
>
> If there is any additional interest, I will post results.  Thanks.
>
>
> [log in to unmask]
>

ATOM RSS1 RSS2