It may be useful to note here for others that auto sense can fail
or just be wrong either way, on the network port (hub/switch) and/or
on the NIC!
Richard
Chuck Ryan wrote:
>
> We have a winner :>
>
> Forcing the switch port to Full Duplex did the trick.
>
> Thanks :>
>
> > -----Original Message-----
> > From: Greg Skvorak [mailto:[log in to unmask]]
> > Sent: Thursday, August 09, 2001 2:00 PM
> > To: Chuck Ryan
> > Subject: Re: Re: 100Base-Tx card
> >
> >
> > Chuck,
> > I ran into a case recently where the BT100 card was defined
> > in NMMGR as full
> > duplex w/o auto sensing. It was the switch that was the
> > problem for me. The
> > CISCO network person set the switch into "auto sense" mode
> > and the HP3000
> > wouldn't communicate. He insisted that meant that the card we
> > had wasn't
> > working properly. I convinced him to set the port to 100mb at
> > which point
> > the HP3000 was fine on the network. I imagine it is some
> > mis-communication
> > issue between the switch and the response (or lack of) that
> > it may get from
> > the HP3000 BT100 card.
> >
> > If you haven't tried the above, it may prove worthwhile as it
> > doesn't take a
> > reboot of the network on the HP, but merely the change in the
> > switch to
> > force it to 100mb.
> > Greg Skvorak
> > Beechglen Development, Inc.
> > Cincinnati, Ohio
> >
> > ----- Original Message -----
> > From: "Chuck Ryan" <[log in to unmask]>
> > To: <[log in to unmask]>
> > Sent: Thursday, August 09, 2001 1:29 PM
> > Subject: Re: 100Base-Tx card
> >
> >
>
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
--
Richard L Gambrell, Director of Computing Systems and Networks
Information Technology Division, University of Tennessee at Chattanooga
Fax: 423-755-4150 Support Help-Desk: 423-755-4000
Direct phone: 423-755-5316 ITD Business Office: 423-757-1755
Mobile (urgent): 423-432-5122 Main UTC: 423-755-4111
Email: [log in to unmask]
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|