To All,
I've recently received patch MPEJXA7 as a means of addressing an SA614 that
we experienced some time ago. The RC engineer was kind of unsure whether
this patch would resolve the SA614 related problem and whether it would have
any 'side effects'. As a safeguard I'd like to be able to 'back out' the
patch if any undesirable 'side effects' materialize.
So what would be the most efficient way to 'back out' the patch? What else
should I include on the SLT tape to quickly 'restore' our HP3K 969/220
mpe/ix 5.0 pp6 to its state prior to the patch's application?
TIA
Regards
Paul Christidis