I hope somebody out there can help me...

I've got a Motorola Codex 3260 modem on our 980 which we use for RJE
transmissions. Today while trouble-shooting I stupidly reset it to
factory defaults, thinking I was only clearing the data buffer. I didn't
set this up, the guy who did is gone (nop longer employed here), and the
only documentation I can find is a think manual which came with the
modem -- no notes that point to how it should be configured.

Anyone who can help, on-list or off, it would be *greatly* appreciated.
I'm on the phone with HP right now, waiting for help, but they're having
trouble even figuring out if it's a hardware or software call! =:-O

Patrick (desparate!)
--
Patrick Santucci
Technical Services Systems Programmer
KVI, a division of Seabury & Smith
Visit our site! http://www.kvi-ins.com
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
"If they try to rush me, I always say, 'I've only got
one other speed -- and it's slower.'"    ~ Glenn Ford