Evan wrote...
>
>Every one in a while we have a problem with jobs using Powerhouse,
>specifically they encounter some kind of severe error -- like a full
>data
>set -- which ought to cause the remainder of the job to flush. Of
>course
>the UDCs for QUICK, QUIZ, QTP, etc. as distributed by Cognos have a
>CONTINUE
>statement just before the RUN statement, so the jobs don't flush.
>
>Have any of you modified the Cognos UDCs to remove the CONTINUE
>statements?
> Did doing so break anything?
>
With each release of Powerhouse, I always spend hours converting the
supplied UDC's to command files.
I hate UDCS. They're terrible things to manage, change, delete.
I love command files. The Cognos UDC's get weirder and weirder with
every release.
If anyone wants, I'll mail them the "converted" command files.
Cheers
Neil