Andres,

        There isn't a job parameter but you could modify the UDC to check to see if
the process is a session or a job (if "!HPJOBTYPE" = "J" then) and then skip
the parts you don't want executed for jobs.

Thanx,
        Jon

-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]]On
Behalf Of Andres j. Ogayar
Sent: Wednesday, September 26, 2001 6:18 AM
To: [log in to unmask]
Subject: OPTION LOGON in UDC


Hi, List!
   We have an HP3000 user whose UDC contains an OPTION LOGON in order to
start ManMan dispatcher when he logs in interactively.

   But, sometimes this user has to be used to execute a batch process, and
in this case, the OPTION LOGON interferes with the rest of the job, so it
is not desires (in batch).

   Is there any parameter which can be used in the job in order to not
execute the OPTION LOGON instruction (but we'd like the rest of the UDC to
be processed properly)?

   Thanks in advance,

    -- Andres j. Ogayar
    -- I.T. Department
    -- Raytheon Microelectronics Espaņa (Malaga, Spain)
    -- +34.95.224.92.27


* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2