It 'could' be am not sure.
These are generated by Fantasia and AventX and either auto-reply or dealt with it in their own special 3rd party way. What I mean is, they have not asked for console replies in years.
We have about 800 printers on our system. It seems only a couple are squeaky-wheels lately.
Tracy Johnson
Office (757) 766-4318
[log in to unmask]
> -----Original Message-----
> From: Mark Ranft [mailto:[log in to unmask]]
> Sent: Wednesday, August 06, 2014 3:02 PM
> To: Johnson, Tracy; [log in to unmask]
> Subject: RE: [HP3000-L] Mysterious Reply Messages on Spool Files
>
> Tracy,
>
> You are right, there is no FORMS designation on the SPOOLID referred to
> in the REPLY, but if a prior spoolfile had asked for special forms, and
> someone replied 'Y'. A REPLY will pop up to request standard forms to be
> placed into the printer. I see that many of the other spoolfiles, some
> at priority 8, have a FORMS designation. Could that be the cause?
>
> Mark Ranft
> Pro 3K
>
> -----Original Message-----
> From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On
> Behalf Of joseph dolliver
> Sent: Wednesday, August 6, 2014 1:42 PM
> To: [log in to unmask]
> Subject: Re: [HP3000-L] Mysterious Reply Messages on Spool Files
>
> Tracy, what does a "showdev" and a "listening" of all your printers. It
> must be coming from how they are configured. Any changes or swaps of
> printers in the recent past? Just saying. "Ioconfig" listed device
>
> Joe
> On Aug 6, 2014 2:23 PM, "Johnson, Tracy" <[log in to unmask]>
> wrote:
>
> > I asked about it last week to no satisfaction and console replies are
> > still coming out of the blue.
> >
> > Notice there is no forms flag (F) on the current file being printed at
> > the top, but yet the console needs a reply. I checked the PIN and it
> > is simply OUTSPTJ and the parent goes to SPOOLMOM. (It must be a
> > single Mom because there is no SPOOLDAD.)
> >
> > I thought I could lay the blame on 3rd party utility software (the
> > kind that generates forms), but this is not a form.
> >
> > THE FOLLOWING REPLIES ARE PENDING:
> > 4:59/1016/SP#2809/IS #J2300; RE992M ON LDEV#2809 (Y/N)?
> > /SYS/PUB%>LISTSPF @;SELEQ=[DEV=2809]
> >
> > SPOOLID JOBNUM FILEDES PRI COPIES DEV STATE RSPFN OWNER
> >
> > #O501258 J2300 RE992M 8 1 2809 PRINT S
> > JBSTRM25.MMV090
> > #O501259 J2301 RE992M 8 1 2809 READY S
> > JBSTRM25.MMV090
> > #O501262 J2303 RE993M 8 1 2809 READY S
> > JBSTRM25.MMV090
> > #O503915 S267 RE993M 8 1 2809 READY S
> NORUMK.MMV090
> > #O503917 S267 RE992M 8 1 2809 READY S
> NORUMK.MMV090
> > #O503935 S267 RE993M 8 1 2809 READY S
> NORUMK.MMV090
> > #O503940 S267 RE992M 8 1 2809 READY S
> NORUMK.MMV090
> > #O503942 S267 RE995M 8 1 2809 READY S
> NORUMK.MMV090
> > #O500302 J3599 UT700FR 2 1 2809 READY S F MGR.STR
> > #O500304 J3599 UT700FR 2 1 2809 READY S F MGR.STR
> > #O500305 J3599 UT700FR 2 1 2809 READY S F MGR.STR
> > #O500306 J3599 UT700FR 2 1 2809 READY S F MGR.STR
> > #O500307 J3599 UT700FR 2 1 2809 READY S F MGR.STR
> > #O500324 J3599 UT700FJ 2 1 2809 READY S MGR.STR
> > #O500286 J613 UT700FF 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500287 J613 UT700FF 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500288 J613 UT700FF 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500289 J613 UT700FF 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500290 J613 UT700FF 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500308 J613 UT700FR 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500309 J613 UT700FR 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500310 J613 UT700FR 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500311 J613 UT700FR 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500312 J613 UT700FR 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500330 J613 UT700FX 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500331 J613 UT700FX 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500332 J613 UT700FX 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500333 J613 UT700FX 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500334 J613 UT700FX 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> >
> > INPUT SPOOL FILES OUTPUT SPOOL FILES
> > ACTIVE = 0; CREATE = 0; READY = 13;
> > OPEN = 0; DEFER = 0; SELECTED = 8;
> > READY = 0; DELPND = 0; SPSAVE = 15;
> > PRINT = 1; XFER = 0;
> > PROBLM = 0;
> >
> > TOTAL IN FILES = 0; TOTAL OUT FILES = 29;
> > IN SECTORS = 0; OUT SECTORS = 7888;
> >
> > OUTFENCE = 7
> > OUTFENCE = 11 FOR LDEV 6
> > OUTFENCE = 11 FOR LDEV 101
> > /SYS/PUB%>RECALL
> > THE FOLLOWING REPLIES ARE PENDING:
> > 4:59/1016/SP#2809/IS #J2300; RE992M ON LDEV#2809 (Y/N)?
> > /SYS/PUB%>REPLY 1016,Y
> > /SYS/PUB%>RECALL
> >
> >
> > Tracy Johnson
> > Business Analyst
> > Measurement Specialties, Inc.
> > Office (757) 766-4318
> > Cell (757) 755-6470
> > [log in to unmask]<mailto:[log in to unmask]>
> >
> >
> > * To join/leave the list, search archives, change list settings, *
> > * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
> >
>
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
>
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|