I seem to recall MPE 5.5 would hang on SHUT 4 for a long time. It was okay to power off then, but one would expect the volume set recovery step of START to take a little longer. It was worth it to wait for SHUT 6 if possible.
Mark Ranft
> On Oct 24, 2022, at 4:43 PM, Robert Liesenfeld <[log in to unmask]> wrote:
>
> I look for “Shut 6” as the indicator that powering off is safe. Pretty
> sure the message for that even says “shutdown complete” or words to that
> effect.
>
>> On Mon, Oct 24, 2022 at 13:18 James B. Byrne <
>> [log in to unmask]> wrote:
>>
>> Is there a positive console confirmation when SHUTDOWN SYSTEM completes
>> (MPE/iX-7.5pp5)? If so then what is it? If not then how does one
>> determine
>> that it is safe to cut the power?
>>
>> --
>> *** e-Mail is NOT a SECURE channel ***
>> Do NOT transmit sensitive data via e-Mail
>> Unencrypted messages have no legal claim to privacy
>> Do NOT open attachments nor follow links sent by e-Mail
>>
>> James B. Byrne mailto:[log in to unmask]
>> Harte & Lyne Limited http://www.harte-lyne.ca
>> 9 Brockley Drive
>> <https://www.google.com/maps/search/9+Brockley+Drive?entry=gmail&source=g>
>> vox: +1 905 561 1241
>> Hamilton, Ontario fax: +1 905 561 0757
>> Canada L8E 3C3
>>
>> * To join/leave the list, search archives, change list settings, *
>> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
>
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|