Yes, stopped and started whole network
Regards,
John Pitman
-----Original Message-----
From: Gilles Schipper [mailto:[log in to unmask]]
Sent: Wednesday, 20 April 2011 8:30 AM
To: John Pitman; [log in to unmask]
Subject: Re: [HP3000-L] no vt mgr connectivity - N series
Are you sure you started up Network services, as in:
nscontrol start
You can check w. nscontrol status.
I'm assuming that netcontrol starts have also been performed.
Check with netcontrol status.
At 05:59 PM 2011-04-19, John Pitman wrote:
>On arrival this morning, I find no reflections connectivity.
>
>Stopped and restarted network, no change. System can ping out to my PC,
>and I can ping it, but no vt-mgr. Nettool->res->disp shows last item
>TCP control pool as maxed out at 2048....
>
>Suggestions short of reboot appreciated.....
>
>Regards,
>
>John Pitman
>
>________________________________
>CAUTION: This message may contain privileged and confidential
>information intended only for the use of the addressee named above.
>If you are not the intended recipient of this message you are hereby
>notified that any use, dissemination, distribution or reproduction of
>this message is prohibited. If you have received this message in error
>please notify RYCO Hydraulics Pty. Ltd. immediately. Any views
>expressed in this message are those of the individual sender and may
>not necessarily reflect the views of RYCO Hydraulics Pty. Ltd.
>
>* To join/leave the list, search archives, change list settings, *
>* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
-------------------------------------------------------------------------------------------------
Gilles Schipper
GSA Inc.
HP System Administration Specialists
300 John Street, Box 87651 Thornhill, ON Canada L3T 7R4
Tel: 416.702.7900
email: [log in to unmask] web: http://www.gsainc.com
-------------------------------------------------------------------------------------------------
CAUTION: This message may contain privileged and confidential information intended only for the use of the addressee named above. If you are not the intended recipient of this message you are hereby notified that any use, dissemination, distribution or reproduction of this message is prohibited. If you have received this message in error please notify RYCO Hydraulics Pty. Ltd. immediately. Any views expressed in this message are those of the individual sender and may not necessarily reflect the views of RYCO Hydraulics Pty. Ltd.
* To join/leave the list, search archives, change list settings, *