Roger said.....

[snip]
> This indeed was the case.  The network people had added a new fiber
cable
> and a new DTC.  Another DTC was power cycled that same day.  The writes
are
> errors indicating 'missing SQE heartbeats' to those two DTCs.
>
> The DTCs are configured with only logging class 1 = 'Y'.  This should be
for
> serious errors only.  The Response Center has contacted the Expert
Center to
> see if 'SQE missing heartbeats' should be included in this logging
class.

We had this problem a while ago when we switched our DTC 48's from Thinnet
to AUI interface (to connect to fiber btw).

Since the DTC that had the problem worked ok, I am assuming that this is
NOT an class 1 logging error.  We always log class 1,2 & 3.

fyi...other DTC's would not download since at that time, we were running
DTCMgr on a 386 and the errors comming from the non SQE DTC interfered
with other downloads.

hope this helps.