Subject: | |
From: | |
Reply To: | Stigers, Greg ~ AND |
Date: | Mon, 13 Apr 1998 14:49:23 -0400 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Here's some fun. Under MPE 55 using COBOL II/iX HP31500A.04.16,
compiling a program with the following inline perform, I get this
Codegen error. Searching the LaserROM for 5705, it seems not to like the
comparison, but I find no good solution for this. I have tried changing
the comparison; for confirmation, I commented out 1048, and could
compile. I edited to just test C-C = ZERO, and got the same error. I
tried ZEROES and 0, and enclosing in parentheses, without success.
Getting clever and defining another identifier with a value of zero is
not legal (EXPECTING ONE OF THE FOLLOWING: <NUMERIC-LIT> ZERO). OK...
GOTO would be messy in this context. Ideas, anyone? Is this just a
genuine bug?
01044 D PERFORM WITH TEST AFTER
01045 * K-INDEX isn't used anywhere else,
so I'll use it here.
01046 D VARYING K-INDEX FROM 1 BY 1
01047 D UNTIL K-INDEX = 10
01048 D OR C-C = ZERO
01049 D CALL INTRINSIC "FCONTROL"
01050 D USING INPUT-FILE-NUMBER \4\
DUMMY-WORD
01051 D END-CALL
01052 D END-PERFORM
...
COBOL ERRORS:
LINE # SEQ # COL ERROR SEV TEXT OF MESSAGE
------ ------ --- ----- --- ---------------
01048 80 384 Q Codegen detected error (5705) at LOC
1048 in testprog Ustack underflow (5705).
01048 80 999 D UNABLE TO CONTINUE. COMPILATION
TERMINATED.
1 ERROR(s), 1 QUESTIONABLE, 0 WARNING(s)
*** DISASTROUS ERROR NEAR LINE 01048 ***
*** COMPILATION TERMINATED ***
CHECKED SYNTAX ONLY.
CPU TIME = 0:00:00. WALL TIME = 0:00:05.
|
|
|