Subject: | |
From: | |
Reply To: | |
Date: | Tue, 28 May 1996 16:10:30 -0400 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Vance Ho wrote:
>Hi, Mike
>
>If yr HP3000 is running MPE/iX 5.0, what u need is to turn the
>DTC power off and then on again. The MPE/iX 5.0 will detect the DTC
>and then download the necessary DTC port config. info into the DTC.
>U should notice that some downloading info appearing at the Console
>Terminal.
>
>If yr HP3000 is running MPE/iX 4 or 4.5, u hv to
>
>a. perform SHUTDOWN on HP3000
>b. power off DTC
>c. start up HP3000 ... at the ISL> prompt, enter STARTNORECOVERY.
>d. After passing thru the system date/time when some system msg
> appears, u need to turn on DTC power. The DTC config from
> NMCONFIG file will then be downloaded into DTC.
Actually, it doesn't matter what release of MPE/iX you are on. You will
still need to do a START NORECOVERY for any configuration changes for
host-controlled DTC to take effect. If your DTC's are managed and controlled
via OPENVIEW DTC Manager, there are certain port configuration changes which
can be changed dynamically without a system re-boot - such as port speed.
-----------------------------------------------------------------------------
Gilles Schipper Voice: 905/889-3000
GSA Inc. Fax: 905/889-3001
300 John Street, Box 87651 Internet: [log in to unmask]
Thornhill, ON Canada L3T 7R4 Compuserve: 71203,474
-----------------------------------------------------------------------------
|
|
|