"Hoxsie, Howard" <[log in to unmask]>
Reply To:
Hoxsie, Howard
Date:
Tue, 5 Feb 2002 13:11:15 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (67 lines)
I had that same problem a couple of weeks ago on my N4000 running 7.0pp1 and I do see the bad patch in my HPSWINFO file.  No one at the RC mentioned anything about the bad patch or the one word fix.  Needless to say I'm following up.  Thanks for the tip!

FYI,
Howard Hoxsie
HPe3000 Systems Administrator
nordstrom.com
www.nordstrom.com
(206) 215-7069 voice (206) 215-7869 fax
[log in to unmask]
600 University Street, Suite 600
Seattle, WA   98101-4102


-----Original Message-----
From: Bill Cadier [mailto:[log in to unmask]]
Sent: Tuesday, February 05, 2002 11:37 AM
To: [log in to unmask]
Subject: Re: [HP3000-L] System Abort 1458


Randy writes:

> John,
>  Do you use StreamX from Vesoft? If yes, we had the following system abort
> on 6.5 pp2 + patches
>
> System Abort 1458 from  Subsystem 102
> Secondary Status: Info=-300, Subsys 107
> System Halt 7, $05B2
>
>  The system abort occurred when there is a typo in the job card and using
> StreamX. You will get the error message "Nil ccb pointer - internal error.
> (CIERR 9016)" when streaming the job with the typo. This corrupts the Job
> Master Table and the next time a process transverses this table, a system
> abort will occur. I think the command SHOWJOB will transverse this table.
>
>  The problem was introduced with patch mpelxv2b, witch is on pp3 for 6.5.
> You may want to call the RC to see if the problem exist on 7.0
>
> Hope this helps.
>
> Randy Breitfelder
> Nielsen Media Research

Forgot about that one!

MPELXV2(C) for 7.0 was marked bad but it is worth being sure it's not
installed. There's a one word binary patch that can be installed to correct the
problem if any version of MPELXV2 is installed. The Response Center should
have all the details.

I should mention that just plain old MPE STREAM can also submit a job with
a malformed JOB card and result in the SA1458 Randy mentioned.

Hope this helps!

Bill
HP/CSY
reply to: cadier at hpixec01 cup hp com
(add the dots and make the 'at' and @ and it'll work!)

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2