text/plain (17 lines)
Gerhard Trampitsch wrote:
>
> Hey HP3000 spezialists.
>
> We have the following problem:
> We coult not open more than 32 NS3000 connection to our HP3000. The
> max. number of connection we didn't reach.
> We have a HP3000/987, MPEix5.0, 100 user. We are using Reflection 1
> V4.2 an the NS3000 Connection  V4.01.

NSCONTROL has a parameter which controls the maximum number of each
server.  The default max for VTSERVER appears to be 300 on MPE/iX 5.5.
Perhaps the command files (or job, or whatever) that you use to do the
NSCONTROL START has a ";SERVER=VTSERVER,something,32" in it?

Or, more likely, someone else will soon post the correct answer!