BC5518 wrote:
>
> What types of Terminal Emulation products are available that will allow
> you to connect to an HP3000 and a IBM mainframe.  I need 70092 terminal
> emulation for  the HP3000 and a 3270 terminal emulation for the IBM.
> Currently I'm using reflection to connect to the HP3000.

  I understand that you want to run two terminal sessions from
reflections, 70092 session on HP3000 and 3270 on IBM. I can suggest one
solution for this.

Do you have an SNA link (TOKEN or SDLC) between your HP3000 and IBM ? If
you have, then start a 70092 session from reflections and then run
TTSSON.PUB.SYS from that session to get a 3270 terminal emulation.
Typical syntax for running this program is,run

 ttsson;info="config=ibmnode#imfclass;devid=t"
where 'ibmnode' is the node name configured in NMMGR and 'imfclass' is
the class name configured.