Gilles Schipper <[log in to unmask]>
Reply To:
Gilles Schipper <[log in to unmask]>
Date:
Tue, 18 Nov 2008 18:32:45 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (24 lines)
It shouldn't be, since logging is disabled.

I've seen normally operating TurboIMAGE databases with invalid log id's.

In such cases, you would NOT be able to start logging without first 
correcting the invalid logid problem - but can operate normally 
without logging.

At 04:35 PM 08-11-18, Tom Emerson wrote:
>just as I was about to post this, I see above here that the LOGID is 
>invalid -- could that be a contributing factor?

-------------------------------------------------------------------------------------------------
Gilles Schipper
GSA Inc.
HP System Administration Specialists
300 John Street, Box 87651   Thornhill, ON Canada L3T 7R4
Voice: 905.889.3000     Fax: 905.889.3001
email:  [log in to unmask]  web: http://www.gsainc.com
-------------------------------------------------------------------------------------------------