Tad Bochan ([log in to unmask]) wrote:
: I did perform the RTFM bit myself , and read the part which you have
: included in your post.
: HOWEVER, such secondary entry points are apparently only
: permitted in subprograms and not in main programs, and are not
: able to be referenced via the entry parameter on the Run command.
That used to be true, but a recent enhancement now permits the ENTRY
statement to be used in a COBOL II/iX main program as well. The
alternate entry point can be specified on the RUN command. You need
version A.04.19 of the compiler.
This was one of the enhancements requested by SIGCOBOL. You'll
find documentation in the MPE/iX 5.5 PowerPatch 5 Communicator or
the MPE/iX 6.0 Communicator.
If you're on an older version of 5.5, you can get this functionality
by ordering patch COBKXA2.
Walter Murray
Hewlett-Packard
Support Technology Lab
COBOL II/iX Project