HP3000-L Archives

May 2000, Week 3

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Kurt Sager <[log in to unmask]>
Reply To:
Kurt Sager <[log in to unmask]>
Date:
Mon, 15 May 2000 18:52:37 +0200
Content-Type:
text/plain
Parts/Attachments:
text/plain (112 lines)
It turned out that after the disk replacement at our customers
site, the engineer did pick-up an old MPE 5.0 SLT to initialize
the system, then a restore of all the remaining files
(restore *t;@[log in to unmask]@;keep;olddate,create;creator;show=offline)
was done from the latest backup of the system, which was
MPE 6.0 before the disk crash ...

Conclusion: never mix up OS versions!

Thanks anyway to all who replied!

Kurt

_______________________________________________________________
Kurt Sager
SWS SoftWare Systems AG, Freiburgstr. 634, CH-3172 Niederwangen
Phones: 031 9810666  / 079 607 7085     Fax: +41 (0) 31 9813263
mailto:[log in to unmask]           home page: http://www.sws.ch




>-----Original Message-----
>From: Kurt Sager
>Sent: Montag, 15. Mai 2000 16:31
>To: Raymond Roesch; Patrik Renout (E-mail 2)
>Cc: Roman Sallin
>Subject: FW: Problem with STREAM
>
>
>Bitte im DMI kontrollieren.
>
>Kurt
>
>-----Original Message-----
>From: Robert Mills [mailto:[log in to unmask]]
>Sent: Montag, 15. Mai 2000 15:15
>To: [log in to unmask]
>Subject: Re: Problem with STREAM
>
>
>Kurt,
>
>Here are the time settings on our machines. Yours should be
>similar once you
>have allowed for the time-zone difference. Note that we are
>located 16 miles
>away from Greenwich.
>
>mgr.telesup: showclks.pubxl
>SHOWCLKS/XL  A.10.00
>DEBUG/iX C.05.08
>
>HPDEBUG Intrinsic at: 1315.00007258 PROGRAM+$198
>PRIV=$3 := $0
>
>  *************************************************************
>  ***                                                       ***
>  ***   Greenwich Mean Time : MON, MAY 15, 2000, 12:56 PM   ***
>  ***   GMT/MPE offset      : +1:00:00                      ***
>  ***   MPE System Time     : MON, MAY 15, 2000,  1:59 PM   ***
>  ***                                                       ***
>  *************************************************************
>
>                 **** C Library Information ****
>
>        Current value of Time Zone(TZ) variable : GMT0BST
>        CTIME function return :  Mon May 15 13:59:08 2000
>
>mgr.telesup: showclock
>
>SYSTEM TIME: MON, MAY 15, 2000,  1:59:44 PM
>CURRENT TIME CORRECTION:            0 SECONDS
>TIME ZONE:    1 HOURS  0 MINUTES EASTERN HEMISPHERE
>
>mgr.telesup: showtime
>
>MON, MAY 15, 2000,  1:59 PM
>
>mgr.telesup:
>
>Regards,
>Robert W.Mills (Windsong Services)
>
>-----Original Message-----
>From: Kurt Sager [mailto:[log in to unmask]]
>Sent: Monday, May 15, 2000 1:20 PM
>To: [log in to unmask]
>Subject: Problem with STREAM
>
>
>On a simple HP/917LX system, after a disk replacement,
>and reload, we can't stream anymore.
>
>stream anyjob;in=,1
>
>or
>
>stream, ! ;in=,1
>
>results in the strange message:
>
>:stream ,!;in=,1
>Specified time is earlier than the current time.
>   job(s) will be STREAMed immediately. (CIWARN 6355)
>>
>
>Why should time-now + 1 hour be earlier than the actual time???
>
>Kurt
>

ATOM RSS1 RSS2