Subject: | |
From: | |
Reply To: | Newton, Ernie |
Date: | Mon, 28 Feb 2000 13:03:10 -0800 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Tony White wrote me personally...
<snip>
We were told to also set the JCW VSETNEXTCENTURY0 = 2. That's a zero at the
end.
</snip>
THAT DID IT!! Thanks Tony and to all else who answered.
Ernie
> -----Original Message-----
> From: Newton, Ernie
> Sent: Monday, February 28, 2000 12:09 PM
> To: [log in to unmask]
> Subject: leap year
>
> Greetings,
>
> We are having a problem with VPLUS recognizing 2/29/00. I've contacted HP
> and they suggested that the JCW VSETNEXTCENTURY = 2 should be set as a
> system-wide UDC. I have placed it in the logon UDC to execute when
> anybody logs on and it works, but we are still having trouble. Any
> suggestions?
>
> The error we get is "The field must be a valid date, in MDY order.(YEAR =
> YYYY)" , with RCA100.
>
> We are currently on 5.5 with powerpatch 6 and I've also installed the
> VPLKXR3 patch.
> We also have FORMSPEC/V B.06.07
>
>
> Thanks,
>
>
> Ernie Newton
> Computer Systems Specialist
> Yolo County Office of Education
> [log in to unmask]
|
|
|