Isaac Blake ([log in to unmask]) wrote:
: Item Subject: Message text
: > Yes...HP sent a document clearly describing the problem...I received
: > mine months ago (with a pre-release of 5.0 Push). I can't vouch
: > for whether or not regular 5.0 Push people received such a document.
: Stan I received the document as well and it was in the 5.0 Communicator,
HOWEVER
: it addressed a problem with firmware version 7.11 and *NOT* with version
11.16,
: so...
: /isaac
Perhaps I can clear this one up. If its a SCSI DDS drive, the
required firmware is 10.7 (later firmware doent work either, at
least for the moment). The firmware can be updated easily via a
"special" tape by a CE. If its a HPIB DDS drive, the correct
firmware is version C, but this requires actual disassembly
of the drive to update.
Be sure to check this out well in advance. Nobody likes
surprises.
--
Mike Ryan @ Hewlett Packard Co. Internet: [log in to unmask]
Burlington Phone: (617) 221-5213
29 Burlington Mall Road HP Telnet: 221-5213
Burlington, MA 01803 HP DESK: [log in to unmask]
------------------------------------------------------------------------------