Remove the memory card (and its associated other half), and try again.

Because it should work with a little bit less memory.

You 'may' also have to shuffle other memory pairs from the end of the memory carrier to the empty slots.  (I don't think it likes gaps in the memory carrier.)

Then buy another memory pair, wait for the next reboot and put new ones in.

Tracy Johnson
+00 1 757 766-4318 tel
+00 1 757 755-6470 mobile
Hampton, Virginia, U.S.
[log in to unmask]

> -----Original Message-----
> From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On Behalf
> Of James B. Byrne
> Sent: Wednesday, May 03, 2017 8:42 AM
> To: [log in to unmask]
> Subject: [HP3000-L] [URGENT] HP3000-918/LX system failure
> Importance: High
> 
> OS=MPE/iX-7.5pp5
> 
> Last evening we had a prolonged power outage which exhausted our UPS.
> Upon restoration of power the HP3000 restarted and, according to the console
> display, completed a warm restart without incident.  However, at some point
> thereafter the system halted with the following display:
> 
> HPMC Error Log Information
> 
>   Timestamp = Wed May 3 02:32:34 GMT (20:17:05:03:02:32:34)
>   HPMC = 7000
> 
> I/O Module Error Log Information
> 
>   Bus     Slot    HPA   Module Type      Estat   Severity
>   ---     ----    ----- -----------      -----   --------
>   Private  3A           Proc Dep Memory  0x19
> 
>   Responder = 0x13b22e0
> 
> FLT 503F
> 
> How do I proceed to bring back the system?
> 
> 
> 
> --
> ***          e-Mail is NOT a SECURE channel          ***
>         Do NOT transmit sensitive data via e-Mail  Do NOT open attachments
> nor follow links sent by e-Mail
> 
> James B. Byrne                mailto:[log in to unmask]
> Harte & Lyne Limited          http://www.harte-lyne.ca
> 9 Brockley Drive              vox: +1 905 561 1241
> Hamilton, Ontario             fax: +1 905 561 0757
> Canada  L8E 3C3
> 
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2