We have had to use TERMDSM  a bit lately and there are several causes:

Sometimes this is because the power browns out and the HP3000 (ups works
just fine) does not go down but the peripheral devices do and it hangs the
port.

Sometimes this is an indicator that the port on the DTC is getting ready to
go.

I also have problems with a port when a user does not exit gracefully when
signing off for the day.

How have you been doing the shutdown on that device?

Hope this helps,
Catherine Litten,
Senior Programmer Analyst
Valley Presbyterian Hospital
www.valleypres.org
*********************************
The thoughts, comments, and opinions expressed herein are mine.  They do not
reflect those of my employer, nor anyone else.
***This E-mail is covered by the Electronic Communications Privacy Act, 18
U.S.C. §§ 2510-2521 and is legally privileged. This information is
confidential information and is intended only for the use of the individual
or entity named above. If the reader of this message is not the intended
recipient, you are hereby notified that any dissemination, distribution or
copying of this communication is strictly prohibited.  If you have received
this transmission in error, please notify the sender immediately by return
electronic transmission and then immediately delete this transmission.***


-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]]On
Behalf Of Bruce Collins
Sent: Thursday, February 13, 2003 12:02 PM
To: [log in to unmask]
Subject: Abortio Error


I have an application that opens a DTC connected to an X.25 pad and then
transmits information back and forth with another computer. Every evening it
shuts down for the backup and restarts the next morning.

Since Monday, it hasn't been restarting properly. It hangs when it tries to
do an FOPEN on the device. An abortio on the device gives me an error:

HLIO internal error. Command cannot be executed. (CIERR 3161)

which I've never seen before. I have to reset the LDEV with TERMDSM before I
can reconnect.

I've been able to determine that as soon as the application FCLOSE's the
device and terminates, the device is already in this broken state. Although
at this stage a SHOWDEV indicates that the device is available, an ABORTIO
will give me the above error until I reset the LDEV.

Does anybody know what the error message means, and what I might be doing
wrong?

Thanks in advance,

Bruce

(Oh yeah, Work for Peace)
-------------------------------------------------------------------------
Bruce Collins              <[log in to unmask]>
Technical Specialist   Phone : (416) 868-6550 Ext. 24