Subject: | |
From: | |
Reply To: | Skeet, Nigel |
Date: | Tue, 15 Feb 2005 13:41:24 +0100 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
LOGTOOL is in DIAG.SYS on 6.0 and below. If you're on 6.0 or lower you
need to run it through SYSDIAG. In 7.5 it's in PUB.SYS and you should be
able to run it from the CI.
Make sure the LOGT000.PUB.SYS MGCAT file exists, if it doesn't then
LOGTOOL will exit without error.
Nige...
-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On
Behalf Of Gibson Nichols
Sent: 14 February 2005 22:03
To: [log in to unmask]
Subject: [HP3000-L] LOGTOOL just exits
I have a system which won't run LOGTOOL. It just exits - no error
message. So, what is needed to get it to work? I assume I'm missing
some files. Example: :RUN LOGTOOL.PUB.SYS
END OF PROGRAM
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|
|
|