Subject: | |
From: | |
Reply To: | |
Date: | Tue, 4 Jul 2000 10:11:14 -0400 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Steve Belkacem wrote:
>
> Does this mean I can run an ISDN router directly of an
> HPe3000 ?
Certainly, with a few caveats (not set in stone):
* Point-to-point ISDN over [a] designated B-channel[s] would be fine,
but you may have problems if you complicate the configuration (like
multiple dialout profiles, dial-in provisions, etc., where there
may be no channel available when needed).
* If you plan to have a DTC on the other end, you'll have to bridge.
This will likely keep the channel open 24x7 (bad if you're paying
by the minute) and congest the link.
* If you're doing dial-on-demand, set the dialer threshholds rather
liberal; the 3000s TCP stack is rather fickle with flapping links.
Otherwise you should be fine, it's not much different from a slow serial
or frame relay link. [Disclaimer: haven't done this myself
with ISDN on the 3000 end, but I do this almost daily with ISDN on
my end. Slow serial link yes, ISDN no.]
Dialout ISDN is often used as a failover link for a leased line, so
there are perhaps some users with this configuration that can verify
that it works.
Jeff Kell <[log in to unmask]>
|
|
|