Another case of invalid pointer in VSM (-31/107), this tyime handled by ports (122). Yet another case where dumpreading would be useful. Do you have a memory dump ?

Christian Lheureux
Directeur BU Infrastructure / Manager of IT Infrastructure BU
________________________________


  29, rue de Rosières
  91240 SAINT-MICHEL-SUR-ORGE
  FRANCE

  Téléphone :
+33 1 69 72 12 83
  Fax :
+33 1 60 15 30 62
  Email :
[log in to unmask]
  Web : 
www.btwcomputing.com
________________________________

En mai 2004,APPIC RH devient BTW Computing, une activité du Groupe BTW
In May 2004, APPIC RH becomes BTW Computing, an activity of the BTW Group 
> -----Message d'origine-----
> De : HP-3000 Systems Discussion [mailto:[log in to unmask]] De la part
> de Brendan Conway
> Envoyé : mercredi 27 octobre 2004 18:23
> À : [log in to unmask]
> Objet : [HP3000-L] HELP!
> 
> For the past few mornings, I get the following Error message on the
> console of my HP 3000, 987sx running MPE/iX 5.5:
> 
> System Abort 725        SubSYS 122
> Secondary Status:        Info= -31, SubSYS=107
> 
> The system has been completely unresponsive when this message is on the
> console, requiring a hard reboot.  As far as I can tell, it happens
> after the backup job begins.  This is consistently the last job that
> runs.  It happened a few mornings about a month ago, and we replaced the
> tape drive.  Everything was good until Monday, Tuesday, and this today.
> 
> Once the system is back up and running things are smooth, but it looks
> like once the backup job starts, out goes the system, the above message
> flashes on the console. Could this have anything to do with the cleaning
> cartridge?  I don't know how old it is, or if it is effective.  How
> often should the drive be cleaned? This new drive is only 3 weeks old.
> The age of the tapes is unknown, possibly very old.
> 
> Any ideas what the Error message means? Where should I start to diagnose
> this problem?  Any help is appreciated!
> 
> -B. Conway-
> 
> PS - Opinions... Is this Hardware (lack of maintainence) or Software
> (OS)?  Would an upgrade to OS 6.0 possibly help, as this might be in our
> future?
> 